Products

  • GIT-450kVA/150kV PD-free AC Dielectric Test Set

    GIT-450kVA/150kV PD-free AC Dielectric Test Set

    The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.

  • RE-MCF Trolley-Type Cable Fault Comprehensive Test System

    RE-MCF Trolley-Type Cable Fault Comprehensive Test System

    RoBot-Eye Series fully integrated cable fault testing system combines multiple functions, including low-voltage pulse distance measurement, high-voltage pulse current distance measurement, acoustic-magnetic induction pinpointing, audio reception pinpointing, and step-voltage pinpointing. It is primarily used for locating faults such as broken wires, short circuits, and ground leakage faults (with ground insulation resistance below 0.5 megohms) in high- and low-voltage buried power cables. It can also identify high-resistance ground faults, flashover ground faults, and detect the depth and path direction of buried cables.

  • OVT-80K    Insulation Oil Tester

    OVT-80K Insulation Oil Tester

    OVT-80K Insulating Oil Dielectric Strength Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance.

  • HPCI SER. Primary Current Injection Test Set

    HPCI SER. Primary Current Injection Test Set

    HPCI SER. Primary Current Injection Test Set uses digital control technology, with strong anti-interference ability.It features a low-power, high-capacity auto-coupled voltage regulator and a current transformer built with a high-permeability iron core, resulting in high output power, compact size, and light weight. It is mainly used for primary busbar protection and various current transformer ratio tests, and is widely used in scientific research, production, and electrical testing at power, railway, petrochemical, metallurgical, and mining companies.

  • GDYT-10/100  Partial Discharge Testing System 10kVA/100kV

    GDYT-10/100 Partial Discharge Testing System 10kVA/100kV

    This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.

  • TWR-S  Transformer Turns Ratio Tester

    TWR-S Transformer Turns Ratio Tester

    TWR-S Transformer Turns Ratio Tester  can be used for three-phase transformer testing in power systems, especially for Z-type winding transformers, rectifier transformers and Scott, reverse Scott, and balanced transformer testing in railway electrical systems. It is an ideal transformer ratio group polarity tester for power systems, transformer manufacturers and railway electrical systems.

  • GDKC-15D  Circuit Breaker Analyzer

    GDKC-15D Circuit Breaker Analyzer

    High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15D circuit breaker analyzer is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. 

  • GDYL-12kV/100pF  Calibration Standard

    GDYL-12kV/100pF Calibration Standard

    The Standard Capacitor is a calibration instrument. It is standard capacitor for tan delta. When calibrating the test result, it can be tested as test object. User can compare the measured test result with former result.

  • GDSL-D-5000A/6V Primary Current Injection Test Set

    GDSL-D-5000A/6V Primary Current Injection Test Set

     Primary Current Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy to use and maintenance. 

  • GD-875/877 Thermal Infrared Camera

    GD-875/877 Thermal Infrared Camera

    GD-875/877 infrared camera uses 25μm 160*120 detector, temperature measurement range -20℃–+ 350, 3.5inch TFT LCD screen.

     

     

     

  • GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 gas leakage detector, with non-dispersed infrared (NDIR) technology, is mainly used to pinpoint and measure SF6 leakage on GIS and refilling equipment within power industry. 

     

  • GDWS-311RC SF6 Gas Dew Point Tester

    GDWS-311RC SF6 Gas Dew Point Tester

    GDWS-311RC is ideal instrument when it is necessary to test water content of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument

     

123456 Next > >> Page 1 / 20

Send your message to us:

Write your message here and send it to us